Portable Ethylene Gas Analyzer (CI-900)
The CI-900, C2H4 gas analyzer provides accurate, real-time measurement of ethylene gas concentrations, in a compact package suitable for field and laboratory use. At the core of the instrument is a proprietary nanoporous gold sensor technology that offers extraordinary sensitivity to ethylene, at levels as low as 0.01 ppm in air.
Ethylene, a plant hormone produced in response to stress, ripening or maturity has been a useful agricultural diagnostic indicator for many decades. Traditionally, trace ethylene gas measurements were available only to those users, primarily laboratory researchers, who had access to gas chromatography or similar technologies. The CI-900 has been designed for in vivo studies conducted by field and laboratory researchers as well as post harvest cold storage facility operators who require trace C2H4 gas detection capability.
- The new CI-900 sets the industry standard for precision measurements of ethylene
- Non-destructive measurement
- The CI-900 is 12 inches wide and weighs 10lbs
- Features
- Specifications
- How It Works
- High sensitivity down to a few ppb
- High sensitivity to ethylene with little to no cross sensitivity
- Real-time, continuous measurement
- Built in sampling pump
- Quick connections for air inlet and outlet
- User adjustable sampling rate
- Compact and portable
- Internal data logging and storage
- Serial data link - RS-232
- Rechargeable battery
- Front panel display with alarm and status indicator
- Features
- Specifications
- How It Works
| Sensor Type | Electrochemical |
| Air Sampling Rate | 250 ml/min |
| Sampling | Adjustable from 1 per minute to 1 per day |
| Nominal Range | 0-100 PPM |
| Resolution | 0.010PPM |
| Accuracy | ±5% of reading; Automatically corrected for temperature and humidity |
| Display | Graphical LCD with backlight |
| Power Output | 120VAC, 0.1 Amps |
| Operating Environment | 5°C to 45°C (40°F to 115°F)10-90% Relative humidity |
| Battery Capacity | Rechargeable battery for 8-hour operation |
| Dimensions | 12"W v 5"H x 11"D |
| Weight | 10 lb |
| Enclosure | Painted Steel |
| Data Logging and Networking | Internal storage > 10,000 data points; Support for removable USB flash drive; Optional software for offline data analysis; Networking: RS-232, 0-10v analog output, USB; Export to spreadsheet |
| Warm-up Time | Less than 10 minutes |
| Air Sampling Ports | Quick connects standard on inlet and outlet |
- Features
- Specifications
- How It Works
Continuous sampling from a jar containing a single apple, pear or avocado is possible for measurement of the rate of production of ethylene (breathing rate). It is important to know the ethylene production rate of fruit prior to and during storage. For example, late harvest apples may produce too high of ethylene (e.g. =1 µl kg-1 h-1 in CA conditions) to provide long term storability. CI-900 provides the accuracy and a real time response necessary to provide measurements in a CA room, in the field, or in a laboratory environment.
The analyzer provides extremely linear response at low ethylene concentrations of below 10ppm. This linearity is critical for simple calibration and measurement over a wide range of concentrations.
- Features
- Theory Of Operation
- Specifications
- How To Use It
- How It Works
- What's In The Box
Simply clamp the CI-710LP onto the desired leaf to yield a full complement of spectrographic data on leaf transmission, reflectance, and absorbance. The CI-710 has many applications in agriculture and environmental studies; including monitoring moisture content in leaves and protein content of crops.
- Features
- Theory Of Operation
- Specifications
- How To Use It
- How It Works
- What's In The Box
- CI-710 Spectrometer Main Unit
- CI-710 Leaf Probe
- Extra light bulb
- Communication Cables
- Operation Software